AC and DC non inductive current shunt |
Powertek UK Tel: +44 1788 519911 US Tel: +1 631 744 0294 Email: info@powertekuk.com |
return to
homepage | info@powertekuk.com | contact us
Option 02F/B non inductive current shunts
|
|
|
|
About the option 02F/B
non-inductive shunt World-wide
Traceability |
|
|
Option 02F/B
current shunt specifications
| Phase | |||
| Accuracy (23º ± 5ºC)al) | 0.1Hz to 99Hz | ± 0.02º | |
| 100Hz to 999Hz | ± 0.04º ± 0.005º/kHz | ||
| 1kHz to 99kHz | ± 0.05º ± 0.005º/kHz | ||
| Frequency | Range | DC to 100 kHz | |
| Amplitude accuracy | ±0.3% (23ºC ± 5ºC) | ||
| Inputs | Current ranges and nominal resistance | 10mA-2Arms (0R50), 10A (0R02), 20A (0R01) and 50Arms (0R001) | |
| Bandwidth | DC to 100kHz | ||
| Isolation (inputs to ground) | n/a | ||
| Environment | Temperature | Operating | -20ºC to +70ºC |
| Storage | -40ºC to +85ºC | ||
| Humidity (non-condensing) | 10% to 90% RH | ||
| Dielectric Strength | Inputs to case | 1.5kV AC 50/60Hz 1 minute | |
| Mechanical | Weight | 0.2kg | |
| Dimensions (W x H x D) | 215mm x 144mm x 390mm | ||