Powertek Logo
UK Office:
US Office:

Series SDN Non Inductive Coaxial Shunt, CVR

Co-axial Shunt, Current Viewing Resistor (CVR) Series SDN, PCB Mounting

Read more Get a quote

series sdn coaxial shunt
Series SDN non inductive co-axial current shunt
  • Ideal for GaN applications
  • 0.01A to 50Arms continuous
  • 500Arms for 10mS (depending on model)
  • DC-100 MHz frequency range
  • Extends current range of DSO, Scopes, DAQs and Wattmeters
  • Use with phase angle meters and wattmeters
  • BNC, GR, UHF, N, HN and C connectors
  • Insulated enclosure optional
  • Traceable to international standards via NIST (USA) and UKAS (UK)
  • Lifetime warranty
SERIES SDN CURRENT VIEWING RESISTORS SPECIFICATIONS

WIDE BANDWIDTH - HIGH FREQUENCY - ULTRA LOW PHASE SHIFT

series sdn current viewing resistor
 

Small terminating type CVR available with BNC, GR, UHF, N, HN and C connectors
Other connector options available upon request
Standard connections are the "S" input (8-32 stud with threaded case) BNC output connector

SPECIFICATIONS

2 Watt Units - 1 7/8 Inch Overall Length

Model Resistance ohms Bandpass MHz. Risetime nsec. Emax joules
SDN-001 0.001 12 30 12
SSDN-001 0.001 12 30 12
SPT-001 0.001 12 30 12
SDN-0025 0.0025 12 30 28
SSDN-0025 0.0025 12 30 28
SPT-0025 0.0025 12 30 28
SDN-005 0.005 400 1 3
SSDN-005 0.005 400 1 3
SPT-005 0.005 400 1 3
SDN-015 0.015 1200 0.30 1.5
SSDN-015 0.015 1200 0.30 1.5
SPT-015 0.015 1200 0.30 1.5
SDN-10 0.10 2000 0.18 2
SSDN-10 0.10 2000 0.18 2
SPT-10 0.10 2000 0.18 2

3 Watt Units - 3 Inch Overall Length

Model Resistance ohms Bandpass MHz. Risetime nsec. Emax joules
SDN-25 0.25 1200 0.30 5
SSDN-25 0.25 1200 0.30 5
SPT-25 0.25 1200 0.30 5
SDN-50 0.50 800 0.45 2.5
SSDN-50 0.50 800 0.45 2.5
SPT-50 0.50 800 0.45 2.5
ORDERING INFORMATION

When ordering specify model number, wattage output connector and tolerance
Example: SDN-25, 3 Watts, BNC, 4%

About the Series SDN Current Viewing Resistor / Non Inductive Coaxial Shunt

The Series SDN range are non inductive shunts designed to operate over a wide bandwidth, with both AC and DC power systems, especially where phase angle and propagation delay is a consideration, crucial during impedance measurements and power calibration systems. Very useful for adding or extending the current range of Power Analyzers, Wattmeters, Phase Angle Meters, Frequency Response Analyzers and Multimeters.  Using the Series SDN with phase angle meters allows phase angle measurement between voltage-voltage, voltage-current or current-current, ideal for phase protection relays, energy meters and current transformer calibration.

CVR's are rugged high frequency resistors designed to sustain very high peak power and current inputs generated by capacitor banks, pulse generator systems and steady state current loads. Their linear response over a broad frequency band provides an accurate indication of current magnitude free from inductive components. Inherent in CVR design is a coupling between the major electrical parameters of resistance, bandpass, energy capacity and wattage rating. This means we provide a wide ranging series of standard units covering a broad range of specifications.

WATTAGE RATING

Although most CVR's are designed primarily for surge current measurements, their rugged construction and their low temperature coefficient resistive elements have made them ideally suited to a number of steady state applications. An average wattage rating applicable to continuous current loading is thus quoted for each resistor series. Care should be taken in circuitry involving either AC or high duty cycle pulse currents that this rating not be exceeded, since CVR damage by overheating can result. If requested we can supply resistors with special construction which will increase the standard wattage rating to a high value depending on the model.

FREQUENCY RESPONSE

Bandpass of a CVR is essentially flat from DC to an upper limit determined primarily by skin effect in the resistive element. Associated bandpass is based on a measured 10% to 90% risetime response to a step function of current produced by a coaxial line pulse generator. The di/dt of the test pulse exceeded 10^12 amps/sec.

RESISTANCE VALUES

Unless otherwise specified, resistors are supplied with resistance tolerance of ±4% of nominal value. In addition, a Kelvin Bridge determination of its exact resistance, accurate to ±0.2% is supplied with each unit. A wide range of special resistance values for any of our standard units can be supplied.

MECHANICAL DESIGN

Case construction of all coaxial CVRs is silverplated brass. Standard output signal connector is BNC with other connectors available. Large coaxial CVRs utilize a high current flange and coaxial threaded stud input connections. Powertek's flat configuration CVRs, the Series W, originally developed for flat plate transmission line installation, are available in a wide range of unit widths and input configurations and have been found to be particularly useful in applications requiring resistors with extreme energy and wattage ratings.

World-wide Traceability

All measurements made using the CVR series SDN shunts are traceable to National and International standards; through the measurement standards of Powertek. All CVR series SDN shunts are supplied with a certificate of conformance necessary for quality assurance standards such as IEC17025/ISO9001. Independent measurement certification is possible using UKAS, A2LA or Z540/NAVLAP certificate.

Non inductive Co-Axial Current Shunt - CVR applications

  • Ideal for measuring nS Rise and Fall time with GaN devices
  • Pulsed current applications
  • Calibration laboratories
  • Current sensing for phase meters and wattmeters
  • Three phase phase angle indicators V-A
  • Power factor meters
  • High Frequency Watt Meters
  • Extending current range of wideband power meters
  • Power analysis
  • Use as phase reference with current transformer calibration
  • Current probe phase delay characterization
  • SCR current measurements
  • Current control of automatic welders
  • Fault current detection to determine bearing wear of ac generators
  • Electron beam welding
  • Current detection in detonation systems
  • Three-phase fault testing in power transmission substations
  • Fault detection in modulators
  • Measurement of laser system lamp currents
  • IGBT chopper current control in electric cars
  • Circuit breaker testing
Powertek specializes in the design and manufacture of electrical power, voltage and current measuring instrumentation
Contact Powertek today Contact us today