The MC133C model is a compact one-housing three phase
electric power/energy calibrator. It can supply the device under test with
one phase accurate AC voltage and current with calibrated phase shift or
DC voltage and current. Output voltage can be set in five ranges up to
280V and output current in six ranges up to 30A.
Simulated electric power can be set independently in each phase.
Frequency can be set in range from 15Hz to 1kHz with resolution 0.001Hz
to 0.01Hz. Calibrator is equipped with 5 1/2 digital DC meter with DC
ranges 20mA
or 10V for direct calibrating of various types of power transducers.
MC133C calibrator offers two types of defined
distortion of main sinusoidal output signal. The first distortion is
based on adding defined amount of harmonic or inter-harmonic spectral
components up to 5kHz. The second type of distortion is based on
amplitude modulation of output sinusoidal signal by sine or square-wave
modulation signal in frequency range from 0.001Hz to 50Hz. Maximum
depth of modulation is 30%.
Using a supplied cable adapter the current outputs can be
joined together offering one phase current range to 90A AC/DC. |
|
|
|
General technical
data |
|
Voltage range (sine
mode) |
1V to 280V AC
or DC |
|
Current range (sine
mode) |
8mA to 30A AC
or DC |
|
Resolution |
5 1/2 digit |
|
Frequency range |
15Hz to 1000Hz |
|
Frequency accuracy |
0.005% (for
50/60Hz synchronization to mains frequency can be set) |
|
Frequency
resolution |
0.001 Hz bellow
40Hz, 0.01Hz above 40Hz |
|
Distortion of
voltage output |
< 0.05% |
|
Distortion of
current output |
< 0.1% |
|
Phase shift range |
0.000° to 359.99° |
|
Power factor range |
-1.000 to +1.000 |
|
Total electric
power range |
0.03VA to 8400VA |
|
Total electric
energy range |
0.03VAs to 2333VAhr |
|
Time interval
range |
1s to 10000s |
|
Time interval
accuracy |
0.01% + 0.1s |
|
|
SPECIFICATIONS |
|
DC/AC Voltage (sine mode) |
|
Range
|
% of value
+
% of range |
Max.
current
(mA) |
% of value
+
% of range |
Max.
current
(mA) |
% of value
+
% of range |
Max.
current
(mA) |
| |
DC |
DC |
15 - 40Hz
70 - 1000Hz |
15 - 40Hz
400 - 1000Hz |
40 - 70Hz |
40 - 400Hz |
|
1 - 10V |
0.025 + 0.01 |
100 |
0.03 + 0.02 |
100 |
0.025 + 0.01 |
100 |
|
10 - 30V |
0.025 + 0.01 |
200 |
0.03 + 0.02 |
200 |
0.025 + 0.01 |
200 |
|
30 - 70V |
0.025 + 0.01 |
200 |
0.03 + 0.02 |
200 |
0.025 + 0.01 |
300 |
|
70 - 140V |
0.025 + 0.01 |
200 |
0.03 + 0.02 |
200 |
0.025 + 0.01 |
300 |
|
140 - 280V |
0.025 + 0.01 |
150 |
0.03 + 0.02 |
150 |
0.025 + 0.01 |
200 |
|
DC/AC Current (sine
mode) |
|
Range |
% of value
+
% of range |
Max.
voltage
(V) |
% of value
+
% of range |
% of value
+
% of range |
Max.
voltage
(V) |
Max.
voltage
(V) |
| |
DC |
DC |
15 - 40Hz
70 - 1000Hz |
40 - 70Hz |
15 - 400Hz |
400 - 1000Hz |
|
8 - 300mA |
0.03 + 0.01 |
8 |
0.04 + 0.02 |
0.03 + 0.01 |
5.5 |
3.5 |
|
0.3 - 1A |
0.03 + 0.01 |
8 |
0.04 + 0.02 |
0.03 + 0.01 |
5.5 |
3.5 |
|
1 - 2A |
0.03 + 0.01 |
8 |
0.04 + 0.02 |
0.03 + 0.01 |
5.5 |
3.5 |
|
2 - 5A |
0.03 + 0.01 |
5 |
0.04 + 0.02 |
0.03 + 0.01 |
3.5 |
3.5 |
|
5 - 10A |
0.035 + 0.015 |
5 |
0.05 + 0.02 |
0.035 + 0.015 |
3.5 |
3.5 |
|
10 - 30A |
0.04 + 0.02 |
5 |
0.06 + 0.02 |
0.04 + 0.02 |
3.5 |
3.5 |
|
Phase, power factor (sine
mode) |
|
Frequency (Hz) |
Accuracy degrees (°) |
|
15 - 40Hz |
0.1 |
|
40 - 70Hz |
0.05 |
|
70 - 400Hz |
0.1 |
|
400 - 1000Hz |
0.4 |
|
| Accuracy
of power factor: dPF = (1-cos(φ+dφ)/cos(φ) |
|
DC/AC Power (sine mode) |
Accuracy of power is calculated from value
of voltage, current and power factor. |
|
|
Active power (W): dP = square root (dU2 + dI2 + dPF2 + 0.012)
[%]
Reactive power (VAr): dP = square root (dU2 + dI2 + dPF*2 + 0.012)
[%]
Apparent power (VA): dP = square root (dU2 + dI2 + 0.012)
[%] |
| |
Where:
- dP is accuracy of power [%]
- dU is accuracy of voltage [%]
- dI is accuracy of current [%]
- dPF is accuracy of power factor (cos φ) [%]
- dPF* is accuracy of sin φ [%]
|
|
H/I mode – Harmonic/interharmonic products |
|
Fundamental
harmonic frequency range |
15Hz to 1000Hz |
|
Fundamental
harmonic amplitude accuracy |
0.2% of range |
|
Frequency
range of harmonic products |
30Hz to 5000Hz (2nd
to 50th order) |
|
Frequency
range of inter-harmonic products |
15Hz to 1000Hz |
|
Max. number
of harmonic products |
50 |
|
Number of
inter-harmonic products |
1 |
|
H/I products
amplitude range |
max. 30% of RMS
fundamental harmonic amplitude |
|
Amplitude
resolution of H/I products |
0.001% |
|
Noise &
Distortion |
-60dB |
|
Output amplitude accuracy
|
Range |
%
of fundamental harmonic amplitude range |
%
of fundamental harmonic amplitude range |
| |
30Hz to 3000Hz |
3000Hz to 5000Hz |
|
1.0000V to 10.000V |
0.1 |
0.2 |
|
10.0001 - 30.0000V |
0.1 |
0.2 |
|
30.001 - 70.000V |
0.1 |
0.2 |
|
70.001 - 140.000V |
0.1 |
0.2 |
|
140.001 - 280.000V |
0.1 |
0.2 |
|
0.008000 - 0.300000A |
0.1 |
0.2 |
|
0.30001 - 1.00000A |
0.1 |
0.2 |
|
1.00001 - 2.00000A |
0.1 |
0.2 |
|
2.00001 - 5.00000A |
0.2 |
0.4 |
|
5.0001 - 10.0000A |
0.2 |
0.4 |
|
10.0001 - 30.0000A |
0.4 |
0.8 |
|
|
Modulations – Flickers |
|
|
Fundamental
harmonic frequency range |
15Hz to 1000Hz |
|
Single
harmonic (2-50) frequency range |
30Hz to 5000Hz |
|
Modulation
frequency range |
0.001Hz to 50Hz |
|
Modulation
depth |
0.000 to 30.000% |
|
Modulation
depth resolution |
0.001% |
|
RMS
amplitude accuracy |
0.2% of range |
|
Waveform of
modulation signal |
sine, rectangular |
|
Duty cycle
ration of rectangular modulation signal |
1% to 99% |
|
Modulation
depth accuracy |
0.2% |
Built-in process
multimeter |
|
Function |
Range |
Accuracy |
Resolution |
|
DC voltage |
0.0000 to +/-12.0000V |
0.01% of value + 0.01% of range |
100uV |
|
DC current |
0.0000 to 25.0000 mA |
0.01% of value + 0.01% of range |
100nA |
|
Frequency |
1.00000Hz to 15.0000kHz |
0.005% |
10uHz - 0.1Hz |
Accessories |
|
Accessories
(included) |
|
Power cable |
1 pc |
|
Option 10 Test cable banana-banana 1m 1000V/32A black |
1 pc
(3 pcs for three-phase system) |
|
Option 11 Test cable banana-banana 1m 1000V/32A red |
1 pc
(3 pcs for three-phase system) |
|
Option 12 Test cable banana-banana 1m 1000V/32A blue |
1 pc
(3 pcs for three-phase system) |
|
Option 13 Test cable banana-banana 1m 1000V/32A yellow |
1 pc
(3 pcs for three-phase system) |
|
RS232 cable 1.5m |
1 pc |
|
Spare fuse |
1 pc |
|
Interface cable |
2 pcs
(for three-phase system) |
|
Option 133-01 High current adapter |
1 pc
(for three-phase system) |
|
Operation manual, CD |
1 pc |
|
Test report |
1 pc |
|
|
Options (extra
order) |
|
Option 140-50 |
Current coil x25, x50 |
|
Option 10 |
Test cable banana-banana 1000V/32A,1m,black |
|
Option 11 |
Test cable banana-banana 1000V/32A,1m,red |
|
Option 12 |
Test cable banana-banana 1000V/32A,1m,blue |
|
Option 13 |
Test cable banana-banana 1000V/32A,1m,yellow |
|
GPIB cable 2m |
Double shielded 2m IEEE488 cable |
|
POWER |
Application SW for electric power transducers calibration |
|
|
|
|
Download PDFs: |
|
MC133C
datasheet
|
| |
| |
|
|
Return to Homepage |