P Series Variable Frequency Input
Single phase and Three Phase Active Power kW transducer
Powertek
UK Tel: +44 1788 519911
US Tel: +1 631 913 3242
Email : info@powertekus.com
Email : info@powertekuk.com

return to homepage | info@powertekuk.com | contact us

 


Get P-Series Datasheet PDF





  The P series Watt Transducers are designed to measure Active Power in 1 phase and 3 phase systems.  They convert the Active Power taken by a load to an isolated DC output directly proportional to the input power in Watts or KW.  The P Series measure true power and are effectively RMS calibrated transducers, with 4-20mA (4mA live zero) or voltage (0-10V) outputs.  Auxiliary instrument power is required to ensure that the Watts computations are valid, even when the input voltage is varying.  Because the P Series is true RMS sensing, its computation of AC Power is valid even with distorted waveforms of up to 9th harmonic with a crest factor of 5.  The P Series is typically used for Power measurement where distorted current waveforms are present, such as speed controlled pumps, motor controllers, UPS and thyristor drives.  The above units are also used to verify energy management systems, switchboards, generator and telemetery controls.  Isolation of 2.5kV is provided between the input and output signal, allowing the P Series output to be safely connected to PLC computer systems and even conventional analogue meters

FEATURES
  • Accurate from 5Hz to 500Hz, factory
    calibrated
  • Available in both single-phase and
    three-phase configurations
  • Bidirectional input and output
  • Available with split-core current sensors

APPLICATIONS

  • Accurate monitoring of real (active) power that contains dc and non-sinusoidal ac components
  • Variable frequency motor drives
  • Ideal with complex ac signals and phase angle controlled firing circuits

Variable frequency input range (5Hz-500Hz)

SELECTION GUIDE - SINGLE-PHASE (ONE ELEMENT)




SELECTION GUIDE - THREE-PHASE, THREE-WIRE (TWO-ELEMENT)



SELECTION GUIDE - THREE-PHASE, FOUR-WIRE (THREE-ELEMENT)


Solid-core models are supplied with 18-inch cables on sensor sizes C & D. All other solid core models supplied with detachable 8-foot cable. Sensor size C split-core models are supplied with 8-foot attached cable. All other split-core models are supplied with detachable 8-foot cable. Longer cables are available.

 

 



 

ORDERING
All units require 115Vac instrument power 50/60Hz.
Optional 230Vac instrument power - add suffix “-22”
FOR OPTIONAL SPLIT-CORE CURRENT SENSOR
ADD SUFFIX “S” TO PART NUMBER (mention current range)
ADDITIONAL CURRENT RANGES AVAILABLE
SENSOR SIZES SHOWN ABOVE

Return to Homepage